Resist 78

JOTUN · Zinc-Rich Primers

Resist 78 is a Zinc-Rich Primers product from JOTUN, listed in the RichTech multi-brand coating index. This page shows its product category, comparable alternatives from other brands and related application scenarios for fast selection and quoting.

BrandJOTUN
FunctionZinc-Rich Primers
Product nameResist 78
Product familyJOTUN
Product rangeJOTUN

Resist 78 — Technical data (from manufacturer TDS)

Volume solids72 %
Dry film thickness50–90 μm
Theoretical spreading rate14.4–8 m²/L
Density2.5 kg/l
VOC content417 g/L
Number of componentsTwo component
Mixing ratio9 : 2.6 (by volume)
ThinnerJotun Thinner No. 25
Flash point14 °C
TDS issue date25 June 2026

The wording below is reproduced from the manufacturer's English TDS.

Product description

This is a two component moisture curing inorganic zinc ethyl silicate coating. It is a fast curing, very high zinc dust containing product. It conforms to the compositional requirements of SSPC paint 20, level 2 and ISO 12944-5. It provides excellent corrosion protection as part of a complete coating system. It is heat resistant up to 540 °C (1004 °F). To be used as primer in atmospheric environments. Suitable for properly prepared carbon steel substrates only. This product complies with ASTM D520 type II zinc dust.

Typical use

Protective: Suitable for structural steel and piping to be exposed to highly corrosive environments, C5I or C5M (ISO 12944-2). Recommended for offshore environments, refineries, power plants, bridges, buildings and mining equipment. Specially designed as a primer for coating systems where extended durability is required.

Approvals and certificates

Suitable for use in mating surfaces of High Strength Friction Grip Bolted Connections: Complies with the requirements of Research Council on Structural Connections (RCSC) Class B, Appendix A (Slip coefficient and resistance to tension creep).

Data extracted from the manufacturer's published English technical data sheet; copyright remains with the manufacturer. For reference only — confirm against the latest TDS and SDS before ordering or application.

Selection & application notes

  • Zinc-rich primers require blast cleaning to Sa 2½, the specified profile, and a soluble-salt check.
  • Inorganic zinc silicates cure on controlled humidity and need sufficient curing time before overcoating.
  • Too low a DFT weakens cathodic protection; too high increases cracking risk — control against the system's total DFT.

These are general notes for the functional category; confirm parameters against the manufacturer's latest TDS.

More from this brand and function

Equivalent products from other brands

Typical application scenarios

Frequently asked questions

How would you describe Resist 78?

This is a two component moisture curing inorganic zinc ethyl silicate coating.

Which applications suit Resist 78?

Suitable for structural steel and piping to be exposed to highly corrosive environments, C5I or C5M (ISO 12944-2).

Is Resist 78 available in a full colour range?

Per the manufacturer's TDS: grey. Other colours may be available on request; colour availability can affect lead time and minimum order quantity.

What should I check before specifying Resist 78?

It is used as described in the TDS: This is a two component moisture curing inorganic zinc ethyl silicate coating. Confirm primer and topcoat compatibility against the manufacturer's system sheet before ordering.

Need the full TDS or a system recommendation?

Scan to reach our technical team directly. Tell us the product, colour and quantity for system advice and pricing.

Source: manufacturer's published technical documentation. Copyright remains with the manufacturer; always confirm against their latest revision.

Not sure which product fits? Tell us the substrate and service conditions

Share your substrate, corrosivity category and target service life — we will come back with a coating system and quantity estimate.

Contact us