Home/Insights/Selection guide
Selection guide

Cold spray zinc: pushing zinc-rich coatings to the limit

Updated 23 Oct 2026

Cold spray zinc sits between zinc-rich primer and thermal spray: where the ZINDN range fits, what film build it demands, and where it is the wrong tool.

Zinc protects steel along two routes: it keeps the electrolyte away, and it sacrifices itself where the barrier is broken. Hot dip galvanizing and thermal spray rely almost entirely on the second. Conventional zinc-rich primers borrow the same mechanism, but the binder and the film build dilute it. Cold spray zinc is an attempt to close that gap with something that can still be applied like a paint.

What the term actually covers

Cold spray zinc, sometimes sold as cold galvanizing, is a single-component coating with a very high metallic zinc loading, applied by brush, roller or airless spray and dried at ambient temperature. In the better ranges the zinc content of the dry film is typically above 90 percent by mass, and some products claim above 95 percent. At that loading the film stops behaving like a primer and starts behaving like sprayed metal: it conducts, it sacrifices, and it protects the steel immediately around a scratch.

Where the ZINDN range sits

ZINDN organises its zinc products in tiers, and the tier matters more than the product name. The cold spray grades sit at the top of the zinc loading: ZD6310-Z4600 and ZD6310-Z850 on the solvent-borne side, ZDW6810-Z1550 on the water-borne side. Below them are the zinc-rich epoxies such as ZD6075 and ZD6080, which are more forgiving on surface preparation, easier to topcoat and far more common on new-build steel. The inorganic zinc silicates such as ZD2550 go further on heat and solvent resistance, but they demand a properly cured film and a strict overcoating window. Decide which tier you need before you compare model numbers.

Four questions before you specify it

  • Does the exposure justify the zinc loading? Coastal, C4 to C5-M, splash zone and repair of galvanized steel usually do. A heated interior steel at C2 usually does not.
  • Can the surface be prepared and kept clean? Zinc-rich films are unforgiving. Sa 2.5 with a 40 to 70 micrometre profile, and a soluble salt check before the first coat, are not optional.
  • Will the item be welded or cut after coating? Zinc fume from welding through a cold spray film is a health and porosity issue, not a cosmetic one.
  • Is a topcoat acceptable? On most external exposures cold spray zinc is a primer, not a finished system.

Film build is where it goes wrong

Cold spray zinc does not build like a high-solids epoxy. A single pass typically lands around 30 to 40 micrometres, while a C5 exposure often calls for 60 to 80 micrometres in total, which means two or three passes with a recoat window between them. Push one coat too thick and the film mud-cracks; apply too few coats and the welds and cut edges return to being the thinnest part of the job. The arithmetic is simple and it is the step most often skipped on site.

Limits worth writing down

  • Continuous immersion without a topcoat. Zinc dissolves steadily in flowing water and in most chemical services.
  • pH outside roughly 6 to 12.5. Zinc is amphoteric; strong acids and strong alkalis both attack it.
  • Heavy abrasion. A 60 micrometre zinc film is not a wear plate, and it is not a substitute for hot dip where mechanical damage is expected.
  • Large cathodes nearby. Coupled to stainless steel or aluminium in a conductive environment, the zinc becomes the anode for a very large area and disappears quickly.

Application discipline

Four items decide the outcome. The first is preparation: grade, profile and salt, checked and recorded, not assumed. The second is stripe coating, because edges and welds are thin no matter which zinc route is used. The third is the curing condition, which matters especially for silicate-based products, since a dry film is not necessarily a cured film. The fourth is measurement: magnetic gauges read low over a zinc-rich film on a rough substrate, so thickness has to be verified under ISO 19840 rules rather than by a single reading in the middle of a plate.

How to write it into a specification

Name the product and the TDS revision, state the total dry film thickness and the number of coats to reach it, name the topcoat and the interval, and state the acceptance tests. What should not appear is a sentence such as equivalent to 85 micrometres of hot dip galvanizing. The two are close in zinc mass per square metre and not close at all in resistance to mechanical damage, and writing them as equivalents transfers a risk to whoever has to maintain the structure in fifteen years.

On a square metre basis, cold spray zinc costs more in material than a zinc-rich epoxy and less than a full thermal spray operation once mobilisation, masking and surface preparation are counted. That middle position is the whole point: it is the option for the yard that cannot bring a thermal spray crew to site, and for the repair where hot dip is physically impossible.

Sources

  • ISO 12944-2 and ISO 12944-5, public scope (corrosivity categories and protective paint systems)
  • ISO 8501-1, public scope (surface preparation grades and roughness)
  • ISO 8502-3 and ISO 8502-6, public scope (dust and soluble salt assessment)
  • ISO 19840, public scope (verification of dry film thickness on rough surfaces)
  • ISO 1461, public scope (hot dip galvanized coatings, used here only as a comparison of zinc mass per area)
  • Publicly available manufacturer materials — ZINDN cold spray zinc and zinc-rich ranges and their technical data sheets; specific values to be confirmed against the latest TDS

Articles are compiled by RichTech from publicly available manufacturer materials and field practice, for selection reference only; the latest official technical data sheets (TDS) prevail.

Not sure which product fits? Tell us the substrate and service conditions

Share your substrate, corrosivity category and target service life — we will come back with a coating system and quantity estimate.

Contact us